{"id":2590,"date":"2025-05-29T17:55:57","date_gmt":"2025-05-29T09:55:57","guid":{"rendered":"http:\/\/dummy.xtemos.com\/woodmart2\/?p=1238"},"modified":"2026-08-14T17:21:52","modified_gmt":"2026-08-14T09:21:52","slug":"research-on-heat-recovery-from-injection-molding-cooling-water-systems-and-air-conditioning-systems","status":"publish","type":"post","link":"https:\/\/cnhao.tech\/he\/research-on-heat-recovery-from-injection-molding-cooling-water-systems-and-air-conditioning-systems\/","title":{"rendered":"\u05de\u05d7\u05e7\u05e8 \u05e2\u05dc \u05d4\u05e9\u05d1\u05ea \u05d7\u05d5\u05dd \u05de\u05de\u05e2\u05e8\u05db\u05d5\u05ea \u05e7\u05d9\u05e8\u05d5\u05e8 \u05de\u05d9\u05dd \u05e9\u05dc \u05d4\u05d6\u05e8\u05e7\u05ea \u05e4\u05dc\u05e1\u05d8\u05d9\u05e7 \u05d5\u05de\u05e2\u05e8\u05db\u05d5\u05ea \u05de\u05d9\u05d6\u05d5\u05d2 \u05d0\u05d5\u05d5\u05d9\u05e8"},"content":{"rendered":"<div class=\"wpb-content-wrapper\"><div class=\"vc_row wpb_row vc_row-fluid\"><div class=\"wpb_column vc_column_container vc_col-sm-12\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\">\t\t<div id=\"wd-683930640a6a9\" class=\"wd-text-block wd-wpb reset-last-child wd-rs-683930640a6a9 text-left\">\n\t\t\t<p>An injection molding cooling water system is an industrial closed-loop recirculating cooling system that uses cooling water within the range of 20\u00b0C ~ 30\u00b0C as a medium to cool equipment or processes. Its fundamental operational characteristic is temperature reduction control. Essentially, it is understood as a system where cooling water absorbs heat from the load equipment it flows through, then dissipates this heat via cooling units (<a href=\"https:\/\/mp.weixin.qq.com\/s\/wzIhSlPNyYk6T6HkEGtcJw\" target=\"_blank\" rel=\"noopener\">chillers<\/a>) before being recirculated.<\/p>\n\t\t<\/div>\n\t\t\t\t<div id=\"wd-683930b621197\" class=\"wd-text-block wd-wpb reset-last-child wd-rs-683930b621197 text-left\">\n\t\t\t<p>When exploring the comprehensive utilization of thermal energy within the cooling water system, hardware solutions such as installing plate heat exchangers and heat pump units within the cooling network can enable heat recovery and reuse. However, the actual equipment investment and economic return must be carefully considered.<\/p>\n\t\t<\/div>\n\t\t\t\t<div id=\"wd-6839310abe6bc\" class=\"wd-image wd-wpb wd-rs-6839310abe6bc text-left  photoswipe-images\">\n\t\t\t\t\t\t\t<a href=\"https:\/\/cnhao.tech\/wp-content\/uploads\/2021\/07\/wb-blog1.jpg\" data-width=\"1000\" data-height=\"478\">\n\t\t\t\n\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"478\" src=\"https:\/\/cnhao.tech\/wp-content\/uploads\/2021\/07\/wb-blog1.jpg\" class=\"attachment-full size-full\" alt=\"\" srcset=\"https:\/\/cnhao.tech\/wp-content\/uploads\/2021\/07\/wb-blog1.jpg 1000w, https:\/\/cnhao.tech\/wp-content\/uploads\/2021\/07\/wb-blog1-430x206.jpg 430w, https:\/\/cnhao.tech\/wp-content\/uploads\/2021\/07\/wb-blog1-150x72.jpg 150w, https:\/\/cnhao.tech\/wp-content\/uploads\/2021\/07\/wb-blog1-700x335.jpg 700w, https:\/\/cnhao.tech\/wp-content\/uploads\/2021\/07\/wb-blog1-400x191.jpg 400w, https:\/\/cnhao.tech\/wp-content\/uploads\/2021\/07\/wb-blog1-768x367.jpg 768w, https:\/\/cnhao.tech\/wp-content\/uploads\/2021\/07\/wb-blog1-860x411.jpg 860w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" title=\"\">\n\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t<\/div>\n\t\t\t\t<div id=\"wd-6839438c812e3\" class=\"wd-text-block wd-wpb reset-last-child wd-rs-6839438c812e3 text-left\">\n\t\t\t<p>In the field of air conditioning, the recovered heat can theoretically be supplied for space heating. This is feasible, especially in winter when a large portion, or even all, of the heat could potentially be utilized. However, there are two major prerequisites regarding system scale: 1. The installed capacity must be sufficiently large, and 2. The amount of heat available for exchange must be substantial. Regarding process temperature requirements: the cooling water exchange must meet the temperature demands of the injection molding process.<\/p>\n\t\t<\/div>\n\t\t\t\t<div id=\"wd-683943ce8c30f\" class=\"wd-text-block wd-wpb reset-last-child wd-rs-683943ce8c30f text-left\">\n\t\t\t<p>Nevertheless, a significant drawback exists. The period when the industrial cooling water system has its peak cooling demand coincides precisely with the period when the air conditioning system also has its peak cooling demand. Using the systems interconnectedly during these peak periods would increase the required installed capacity of both the refrigeration equipment (chillers) and the cooling units. Therefore, the value of such integration must be critically assessed.<\/p>\n\t\t<\/div>\n\t\t\t\t<div id=\"wd-683943f36bee4\" class=\"wd-image wd-wpb wd-rs-683943f36bee4 text-left  photoswipe-images\">\n\t\t\t\t\t\t\t<a href=\"https:\/\/cnhao.tech\/wp-content\/uploads\/2021\/07\/wb-bolg2.jpg\" data-width=\"1000\" data-height=\"478\">\n\t\t\t\n\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"478\" src=\"https:\/\/cnhao.tech\/wp-content\/uploads\/2021\/07\/wb-bolg2.jpg\" class=\"attachment-full size-full\" alt=\"\" srcset=\"https:\/\/cnhao.tech\/wp-content\/uploads\/2021\/07\/wb-bolg2.jpg 1000w, https:\/\/cnhao.tech\/wp-content\/uploads\/2021\/07\/wb-bolg2-430x206.jpg 430w, https:\/\/cnhao.tech\/wp-content\/uploads\/2021\/07\/wb-bolg2-150x72.jpg 150w, https:\/\/cnhao.tech\/wp-content\/uploads\/2021\/07\/wb-bolg2-700x335.jpg 700w, https:\/\/cnhao.tech\/wp-content\/uploads\/2021\/07\/wb-bolg2-400x191.jpg 400w, https:\/\/cnhao.tech\/wp-content\/uploads\/2021\/07\/wb-bolg2-768x367.jpg 768w, https:\/\/cnhao.tech\/wp-content\/uploads\/2021\/07\/wb-bolg2-860x411.jpg 860w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" title=\"\">\n\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t<\/div>\n\t\t\t\t<div id=\"wd-6839446c96e2f\" class=\"wd-text-block wd-wpb reset-last-child wd-rs-6839446c96e2f text-left\">\n\t\t\t<p>Secondly, utilizing the heat for air conditioning heating introduces a new problem. The industrial cooling water system is a constant-temperature system. When its temperature reaches the control target, the heat exchange from the air conditioning&#8217;s heat pump system must be stopped. This frequently leads to situations in practical application where there is no heat available for the heat pump to recover. Consequently, when selecting air conditioning units, the electrical heating power of the auxiliary heating function in the fan coil units cannot be reduced at all. For systems where the overall recoverable heat is limited, the utilization rate of the recovered heat is low, and the economic return is negligible.<\/p>\n\t\t<\/div>\n\t\t\t\t<div id=\"wd-683944abcb625\" class=\"wd-image wd-wpb wd-rs-683944abcb625 text-left  photoswipe-images\">\n\t\t\t\t\t\t\t<a href=\"https:\/\/cnhao.tech\/wp-content\/uploads\/2021\/07\/wb-bolg3.jpg\" data-width=\"1000\" data-height=\"478\">\n\t\t\t\n\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"478\" src=\"https:\/\/cnhao.tech\/wp-content\/uploads\/2021\/07\/wb-bolg3.jpg\" class=\"attachment-full size-full\" alt=\"\" srcset=\"https:\/\/cnhao.tech\/wp-content\/uploads\/2021\/07\/wb-bolg3.jpg 1000w, https:\/\/cnhao.tech\/wp-content\/uploads\/2021\/07\/wb-bolg3-430x206.jpg 430w, https:\/\/cnhao.tech\/wp-content\/uploads\/2021\/07\/wb-bolg3-150x72.jpg 150w, https:\/\/cnhao.tech\/wp-content\/uploads\/2021\/07\/wb-bolg3-700x335.jpg 700w, https:\/\/cnhao.tech\/wp-content\/uploads\/2021\/07\/wb-bolg3-400x191.jpg 400w, https:\/\/cnhao.tech\/wp-content\/uploads\/2021\/07\/wb-bolg3-768x367.jpg 768w, https:\/\/cnhao.tech\/wp-content\/uploads\/2021\/07\/wb-bolg3-860x411.jpg 860w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" title=\"\">\n\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t<\/div>\n\t\t\t\t<div id=\"wd-6839449f8cd81\" class=\"wd-text-block wd-wpb reset-last-child wd-rs-6839449f8cd81 text-left\">\n\t\t\t<p>Thirdly, integrating the air conditioning units into this heat recovery scheme does not reduce the investment in the core unit equipment. All necessary units (chillers for cooling, heat pumps for heating) must still be installed. It is recommended that clients assess the necessity of heat exchange between the cooling water system and the air conditioning system based on their actual operational demands and current situation.<\/p>\n\t\t<\/div>\n\t\t<\/div><\/div><\/div><\/div>\n<h3>\u05e7\u05e8\u05d9\u05d0\u05d4 \u05e0\u05d5\u05e1\u05e4\u05ea<\/h3>\n<ul>\n<li><a href=\"https:\/\/cnhao.tech\/cooling-water-in-injection-molding-beyond-mere-cooling\/\">cooling water system fundamentals<\/a><\/li>\n<li><a href=\"https:\/\/cnhao.tech\/why-precision-injection-molding-requires-low-temperature-chilled-water\/\">chilled water applications<\/a><\/li>\n<li><a href=\"https:\/\/cnhao.tech\/why-precise-mold-temperature-control-is-critical-for-injection-molding-quality\/\">mold temperature optimization<\/a><\/li>\n<\/ul>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Related Reading cooling water system fundamentals chilled water applications mold temperature optimization<\/p>","protected":false},"author":1,"featured_media":9531,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[96],"tags":[131,143,124,133,142,130,146],"class_list":["post-2590","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog","tag-air-conditioning","tag-auxiliary-equipment","tag-cooling-water","tag-energy-recovery","tag-heat-recovery","tag-plastic-processing","tag-sustainability"],"_links":{"self":[{"href":"https:\/\/cnhao.tech\/he\/wp-json\/wp\/v2\/posts\/2590","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cnhao.tech\/he\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/cnhao.tech\/he\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/cnhao.tech\/he\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/cnhao.tech\/he\/wp-json\/wp\/v2\/comments?post=2590"}],"version-history":[{"count":6,"href":"https:\/\/cnhao.tech\/he\/wp-json\/wp\/v2\/posts\/2590\/revisions"}],"predecessor-version":[{"id":10316,"href":"https:\/\/cnhao.tech\/he\/wp-json\/wp\/v2\/posts\/2590\/revisions\/10316"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/cnhao.tech\/he\/wp-json\/wp\/v2\/media\/9531"}],"wp:attachment":[{"href":"https:\/\/cnhao.tech\/he\/wp-json\/wp\/v2\/media?parent=2590"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/cnhao.tech\/he\/wp-json\/wp\/v2\/categories?post=2590"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/cnhao.tech\/he\/wp-json\/wp\/v2\/tags?post=2590"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}